Part # 4522970 Rev 1 (10/28/09) Page 7
Rigid Connections
Double-check any installer-supplied intake pipes visually
and clear any dirt particles, threading chips, or other foreign
matter before installing in a service line. Those particles will
clog orices when gas pressure is applied.
Flexible Couplings & Connectors
If the unit is to be installed with exible couplings and/or
quick-disconnect ttings, for an appliance equipped with
casters, the installation shall be made with a heavy duty, AGA
design-certied commercial exible connector or at least
3/4” NPT (with suitable strain relief) in compliance with the
Standard for Connectors for Moveable Gas Appliances, ANSI
Z21.69/CSA 6.16, Addenda Z21.69B-2006/CSA 6.16B-2006 (or
latest edition), and a quick-disconnect device that complies
with the Standard for Quick Disconnects for Use with Gas
Fuel, ANSI Z21.41/CSA 6.9, Addenda Z21.41A-2005/CSA
6.16A-2005 (or latest edition), and adequate means must be
provided to limit the movement of the appliance without
depending on the connector and the quick-disconnect
device or its associated piping to limit the appliance
movement and the location(s) where the restraining means
may be attached to the appliance shall be specied.
Further, if the unit is to be installed on a non-combustible
surface that is equipped with casters, means must be
provided to limit the movement of the unit with casters.
Manual Pilot Valve
Check all gas connections for leaks using a soapy solution
before lighting any pilots! DO NOT USE AN OPEN FLAME
TO CHECK FOR LEAKS! Putting an open ame beside a new
connection is not only dangerous, but will often miss small
leaks that a soapy solution would nd.
All Garland appliances are adjusted and tested before
leaving the factory, eectively matching them to sea
level conditions. Adjustments and calibrations to assure
proper operation may be necessary on installation to meet
local conditions, low gas pressure, dierences in altitude,
variations in gas characteristics, to correct possible problems
caused by rough handling or vibration during shipment, and
are to be performed only by qualied service personnel.
These adjustments are the responsibility of the customer,
installer and/or dealer and are not covered by the Garland
warranty.
All burners are equipped with continuous electronic spark
electrodes to insure ame is on at all times during operation.
Continuous sparking is intended to remain energized until
power is manually switched o.
WARNING: All connections must be sealed with a joint
compound suitable for LP gas, and all connections must be
tested with a soapy solution before lighting any pilots!
Start Up
Before initial lighting or if unit does not operate at all check
to see if:
1. Main gas supply shut o to appliance is open.
2. Electric power supply power and cord Nema 5-15P has
been plug into an appropriate 120V 15Amp 60Hz outlet.
For daily start up:
1. Models HEEE-24CL and HEEE-36CL have one power
switch. Once pushed to the “ON” position an igniter
supplies a continuous spark to the burners igniting the
gas to all burners simultaneously. At the same time the
power switch opens up the gas ow to burners.
2. Models HEEE-48CL and HEEE-60CL have two power
switches which operate in the same manner as the
single switch above. Each switch operates separately
allowing the operator to run two sections of the broiler
independently. On the HEEE-48CL the switch on the far
left operates burners 1 to 5. The power switch on the
right will operate burners 6 to 9. On the HEEE-60CL the
left switch controls burners 1 to 6 and the right switch
controls burners 7 to 11.
3. If burners do not ignite, shutdown power to the unit,
and wait 5 minutes before repeating ignition. If repeated
ignition fails, shutdown power to the unit and contact a
service person.
4. Your broiler is an energy saving unit, all burners are pre-
set at the factory to run at a consistent steady ame. No
adjustment should be attempted by the operator.
Shut Down
1. For shutting down overnight, on all models turn the
power switch(es) to the “OFF position.
INSTALLATION Continued