Garland MCO-GD-10E User Manual

Browse online or download User Manual for Thermostats Garland MCO-GD-10E. Garland MCO-GD-10E User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
GARLAND
A WELBILT COMPANY
BUILT TO LEAD... BUILT TO LAST
SERVICE MANUAL
THE “MASTER”
GAS CONVECTION
OVENS
Models covered in this manual are:
MCO-GS-10M:
M
ASTER
C
ONVECTION
Oven - G
AS
S
TANDARD
D
EPTH
-(10)S
INGLE
D
ECK
Manual C
ONTROL
MCO-GS-10E:
M
ASTER
C
ONVECTION
O
VEN
- G
AS
S
TANDARD
D
EPTH
-(10)Single D
ECK
E
LECTRONIC
C
ONTROL
MCO-GD-10M:
M
ASTER
C
ONVECTION
Oven - G
AS
D
EEP
D
EPTH
-(10)S
INGLE
D
ECK
Manual C
ONTROL
MCO-GD-10E:
M
ASTER
C
ONVECTION
Oven - G
AS
D
EEP
D
EPTH
-(10)S
INGLE
D
ECK
E
LECTRONIC
C
ONTROL
GARLAND Commercial Industries, Inc.
185 East South Street
Freeland, Pennsylvania 18224
DIRECT “ON-SITE” SERVICE 1-800-451-1165
GENERAL INFORMATION 1-800-424-2411
FORM #GCI-MCOVN PRINTED IN THE U.S.A.
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - GAS CONVECTION

GARLANDA WELBILT COMPANYBUILT TO LEAD... BUILT TO LAST SERVICE MANUAL THE “MASTER” GAS CONVECTION OVENS Models covered in this manual are: MCO-GS

Page 2

10 The controller needs voltage to operate and is capable of operating on three (3) different line voltages, 115 Vac, 208 Vac, 240 Vac. On the bac

Page 3

11 The User Preference Offset is designed to enable the user to adjust the controlling temperature. There are two different styl

Page 4 - (Top View)

12 Entry Exit UPO - User Preference Offset. Used by the user to adjust the controlling temperature +/- 50º in 1º increments. 1. Set the time di

Page 5

13 The safety lockout timer circuit starts timing the moment the trial for pilot ignition starts. When the timing period runs out, the trial for ig

Page 6 - Chart No.1

14 and answering conditions in each box encountered, until a problem and/or the repair is explained. After any maintenance or repa

Page 7 - Decrease

15 CHECK GROUNDING A common ground is required for the pilot burner, the ignitor-sensor, the GND terminal of the S86, and the

Page 8 - 140-500F

16 APPEARANCE CAUSE SMALL BLUE FLAME Check for lack of gas from: • Clogged orifice filter • Clogged pilot filter • Low gas supply pressure

Page 9

17 This section will give you the best way to access component for replacement. COMPONENT LOCATIONS: Top Front Center Door Chain Door Catc

Page 10

18 2. Locate stainless steel door gasket, mounted to oven front frame. 3. Remove the #10 Phillips sheet metal screw that attach the retainer to th

Page 11

19 2. Remove door chain assembly (NOTE: The “A” model does not come equipped with door chain). 3. Remove flat head metal screw 1/4”-20x1/2”  from

Page 12

2 This service manual is designed to answer questions related to model operational requirements, troubleshooting and disassembly/asse

Page 13

20 123475786NOTICE: DEPENDENT DOOR SHOWN7 To disassemble left door: 1. Once the door has been removed from the oven (refer to instructions on the

Page 14

21 12345NOTICE: DEPENDENT RIGHT HAND DOOR SHOWN. 1. Once the door has been removed from the oven (refer to instructions on page 19), remove 9 truss

Page 15

22 To Replace or Adjust Door Latch Mechanism 1. Open oven doors. 2. Remove 2 pan head Phillips screws. 3. Lift door latch mechanism  up and out

Page 16 - SECTION 3: - A

23 Assembly FILE NAMEJIT000127621385459 1. Assemble  motor mount plate,  * insulation,  motor mount plate inner together by fastening four flat

Page 17 - (Front View)

24 Main Burner, Pilot Burner Removal & Door Micro Switch Location 1234 To access the Burners, Pilot or Door Switch - remove the lower combustion

Page 18 - JIT03418

25 SECTION 4: - COMMON WIRE DIAGRAMS

Page 22 - Convection Oven Motor

3 SECTION 3: COMPONENT ACCESS OF FUNCTIONAL COMPONENTS...16 DOOR GASKET REPLACEMENT...

Page 23 - JIT00012

4 GAS CONVECTION OVEN "GAS SPECIFICATIONS” TOTAL MAIN BURNER ORIFICE PILOT PILOT ORIFICE GAS PRES. W/C B.T.U.'S ORIFICE AMT.

Page 24

5 Understanding the sequence of operation is necessary in properly trouble-shooting this appliance. In this section the sequence of operation w

Page 25

6 A thermocouple type test instrument is preferred for measuring oven temperatures accurately. Mercury thermometers are acceptable providing they

Page 26

7 five times doubling the thickness with each fold. After the fifth fold, place the thermocouple tip in the center of the aluminum piece and fold o

Page 27

8 ELECTRONIC CONTROLS - “E” Sequence of Operation (With the Oven Doors Closed) 1. Line Voltage is supplied to the Mode Switch, Door Switch and

Page 28

9 ELECTRONIC CONTROL FAILURE CODES The GARLAND digital control has a self-diagnostic program. If a problem occurs within the digital controller, y

Comments to this Manuals