PRE INSTALLATION
INSTALLATION
General
1. Carefully remove appliance from carton or crate. Burner
tie wires and other packing material should be removed
at this time. The protective material covering the stainless
steel should be removed immediately after the appliance
is installed, before it is  red.
2. Remove top grates and place out of the way, to prevent
damage.
3. These appliances must be installed under an adequate
ventilation system. Refer to section titled Ventilation for
further instructions.
4. All burner adjustments and setting shall be made by a
quali ed gas technician.
Gas Connections
The local gas authority should be consulted at the
installation planning stage in order to establish the
availability of an adequate supply of gas and to ensure
that the meter is adequate for the required  ow rate. The
pipe work from the meter to the appliance must be an
appropriate size.
All  xed (non-mobile) appliances MUST be  tted with an
accessible upstream gas shut o valve as a means of isolating
the appliance for emergency shut o and for servicing. A
union or similar means of disconnection must be provided
between the gas-cock and the appliance.
A manually operable valve must be  tted to the gas supply
to the kitchen to enable it to be isolated in an emergency.
Wherever practical, this shall be located either outside the
kitchen or near to an exit in a readily accessible position.
Where it is not practical to do this, an automatic isolation
valve system shall be  tted which can be operated from a
readily accessible position near to the exit.
In locations where the manual isolation valve is  tted or the
automatic system can be reset this notice MUST be posted:
ALL DOWNSTREAM BURNER AND PILOT VALVES MUST
BE TURNED OFF PRIOR TO ATTEMPTING TO RESTORE THE
SUPPLY. AFTER EXTENDED SHUT OFF, PURGE BEFORE
RESTORING GAS.
Damage Check
Damage check: Check carton or crate for possible damage
incurred in shipping. After carefully un-crating, check for
concealed” damage. Report any damage immediately to
your carrier.
Rating Plate
The rating plate is a xed to a bracket mounted at the rear
of the unit but visible from the front. The grease drawer may
need to be removed to view rating plate.
The correct type of gas for which the unit was manufactured
is noted on the rating plate, and this type of gas must be
used.
When corresponding with the factory or your local
authorized factory service center regarding service problems
or replacement parts, be sure to refer to the particular model
by the correct model number (including the pre x and
su x letters and numbers) and the warranty serial number.
The rating plate a xed to the appliance contains this
information.
We suggest installation, maintenance and repairs be
performed by your local authorized service agency listed in
your information manual pamphlet.
In the event you have any questions concerning the
installation, use, care or service of the product, write or call
our Product Service Department.
This product must be installed by professional personnel as
speci ed. Garland/U.S. Range products are not approved or
authorized for home or residential use, but are intended for
commercial applications only. Garland / U.S. Range will not
provide service, warranty, maintenance or support of any
kind other than in commercial applications.
Part # 4531237 Rev 2 (09/09/13)